Applies to: MDS manual 05-2806A01
MDS iNET 900 Transceiver
MANUAL SUPPLEMENT
March 2004
Microwave Data Systems Inc., 175 Science Parkway, Rochester, NY 14620 USA
Tel: +1 (585) 242-9600, FAX: +1 (585) 242-9620, Web: www.microwavedata.com
MDS 05-4131A01, Rev. A MDS iNET 900 ENI Supplement 1
This supplement contains additions to the MDS iNET 900 Users Guide (MDS Part No.
05-2806A01). You should include a reference in your User’s Guide to this supplement.
Purpose of this Supplement
This supplement covers the MDS iNET 900 ENI, which provides expanded gateway and protocol
conversion capabilities not found in the MDS iNET 900. Throughout this document, the iNET 900
ENI is referred to as iNET/ENI.
The iNET/ENI currently contains gateway conversion services for:
TCP, UDP, and PPP: Identical to the iNET 900.
DF1 to EIP: Provides EtherNet/IP (Ethernet Industrial Protocol) connectivity for DF1
full-duplex devices.
MODBUS to MODBUS TCP: Provides Modbus TCP connectivity for Modbus RTU or Mod-
bus ASCII Slave devices.
Additional gateway services and protocol support are planned for future firmware releases.
NOTE: This supplement assumes you have an understanding of Ethernet networking and TCP/IP.
1. SELECTING NEW
PROTOCOLS
1 1SELECTING NEW IPPROTOCOLS
Perform the following procedure to select one of the new protocols sup-
ported by the iNET/ENI:
1. Access the MDS iNET’s Serial Configuration Wizard as described
in Section 3.5 of the iNET 900 Users Guide (05-2806A01).
2. Select the IP Protocol screen displays. See Figure 1-1 below.
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - 1SELECTING NEW IPPROTOCOLS

Applies to: MDS manual 05-2806A01MDS iNET 900 TransceiverMANUAL SUPPLEMENTMarch 2004Microwave Data Systems Inc., 175 Science Parkway, Rochester, NY 14

Strona 2

10 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A5. Press A through I (and the up/down arrow keys, if necessary), then enter the desired E-Mail Destin

Strona 3 - PROTOCOL

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 116. Press A through G to select the baud rate you want the iNET/ENI to use when communicating with the

Strona 4 - 2.1.2 Related Documentation

12 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A7. Press A to enable the iNET/ENI’s COM2 port. See Figure 2-7.Figure 2-7 . Enable COM2 Data Port8. Pr

Strona 5 - MDS iNET/ENI

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 139. The Wizard asks you to confirm that you want to save the changes. See Figure 2-9. Press Y to save

Strona 6 - 2.2 DF1/EIP PROTOCOL

14 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A2.3 iNET/ENI Error CodesRefer to Table 2-2 for error codes generated by the iNET/ENI.Table 2-2 iNET/E

Strona 7

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 153. MODBUS to MODBUSTCP SERVER PROTOCOL3.1 IntroductionNOTE: This section assumes you have an understa

Strona 8

16 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A3.2 MODBUS/TCP SERVER CONFIGURATIONPerform the following procedure to configure the MODBUS/TCP SERVER

Strona 9

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 172. Press A to change the MODBUS serial format, then press the space bar to toggle between the availab

Strona 10 - N to continue

18 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A3. Press A through H to select the desired data baud rate. See Figure 3-4.Figure 3-4 Select Data Baud

Strona 11

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 195. Press A to enable hardware flow control. Press B to disable hardware flow control. See Figure 3-6.

Strona 12 - Figure 2-8

2 MDS iNET ENI Supplement MDS 05-4131A01, Rev. AFigure 1-1 . Select IP Protocol Screen3. Do one of the following:• If you selected D) DF1/EIP, refer t

Strona 13

20 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A7. Press X to save the COM2 port configuration changes. See Figure 3-8.Figure 3-8 Save COM2 Configura

Strona 14 - 2.3 iNET/ENI Error Codes

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 213.3 EDS FILE INTEGRATIONThe Electronic Data Sheet (EDS) file must be integrated into the Rock-well So

Strona 15 - TCP SERVER PROTOCOL

22 MDS iNET ENI Supplement MDS 05-4131A01, Rev. AFigure 3-11 . Graphic Image Screen(Default iNET icon shown)Select “Next” to go to the Final Task Summ

Strona 16 - CONFIGURATION

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 32. DF1 to EIP GATEWAYPROTOCOL2.1 Introduction2The MDS iNET/ENI embeds the EtherNet/IP networking funct

Strona 17

4 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A2.1.2 Related DocumentationThis supplement assumes you have an understanding of EtherNet/IP networking

Strona 18 - Figure 3-4

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 52.1.3 Differences Between Allen-Bradley ENI and MDS iNET/ENIThe functional differences between the All

Strona 19

6 MDS iNET ENI Supplement MDS 05-4131A01, Rev. A2.2 DF1/EIP PROTOCOL CONFIGURATIONNOTE: The Rockwell application will not identify the iNET/ENI radiop

Strona 20 - Figure 3-8

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 7Figure 2-2 . Change Security Descriptor Mask3. Press A through I (and the up/down arrow keys, if neces

Strona 21 - 3.3 EDS FILE INTEGRATION

8 MDS iNET ENI Supplement MDS 05-4131A01, Rev. AFigure 2-3 . Enter Destination IP Addresses

Strona 22 - (Default iNET icon shown)

MDS 05-4131A01, Rev. A MDS iNET ENI Supplement 94. Press A to enter the IP address of the optional e-mail server, then press B to enter the E-Mail Fro